Electrical

Wheel blast machines are typically 460 V, 3-phase, 60 Hz in Canada, with 24 VDC controls. Budget 5 HP per wheel plus elevator, separator and conveyor motors; a single-wheel deflash machine runs on a 30 A feed, a four-wheel plate machine needs 100 A or more. We supply a panel certified to the installation jurisdiction.

Compressed air

Deflash machines use about 15 CFM at 80 PSI for doors, seals and blow-off. Air blast cabinets and booths are the big consumers: plan 50 to 250 CFM per nozzle depending on nozzle size and pressure.

Ventilation and dust

Every machine needs a dust collector sized to its hoppers and seals: roughly 900 CFM at 6 in static for a tumble belt machine, 2,000 to 6,000 CFM for wheel blast lines. Collectors are usually outside or in a dedicated enclosure with ducting.

Floor and foundation

Machines sit on a level, 6 in minimum reinforced slab. Plate and structural machines may need a pit for the hopper or a raised conveyor line. Point loads come with the layout drawing.

Ceiling and access

Elevators and separators make these machines tall: 11 to 12 ft for a tumble belt, 16 to 20 ft for a plate machine with its elevator. Check door widths and the route from the dock.

Pre-installation checklist

Our documentation page has the checklist we send with every order.

Receiving and rigging

Check the route from the truck to the cell: door width and height, floor loading on the way, crane or forklift capacity and turning room. Tall machines often arrive with the elevator and separator removed and are stood up on site, which needs headroom above the final height during the lift.

Pits and foundations

Larger wheel machines and booths with full recovery floors may sit over a pit that houses the abrasive hopper and screw conveyors. The pit must be dry, drained or sumped, and built to the foundation drawing before the machine arrives. Machines designed to sit on the floor avoid the pit at the cost of a taller profile.

Noise

Blast machines are loud at the cabinet and at the collector fan. Plan hearing protection for operators and consider where the collector sits relative to offices and neighbours. Acoustic treatment is easier to design in than to add.

Environmental and safety approvals

Dust collectors that exhaust outdoors may need an environmental approval depending on your jurisdiction and the material processed. Electrical equipment must carry an approval mark accepted where it is installed. Combustible dusts, including aluminium and some plastics, bring their own code requirements for collectors and ducting. Raise these early with your own health, safety and environmental staff.

Space for service

Leave room to open doors fully, pull wheel assemblies, remove elevator belts and change filters. A machine packed tightly against a wall is cheaper in floor space and more expensive at every maintenance visit.